Trial reportIntensive care medicine2005
A new device for administration of continuous positive airway pressure in preterm infants: comparison with a standard nasal CPAP continuous positive airway pressure system.
Trial report in Intensive care medicine, 2005. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 2 syntheses or guidelines pooled it, 46 citations in OpenAlex.
- Masks versus prongs as interfaces for nasal continuous positive airway pressure in preterm infants.The Cochrane database of systematic reviews · 2022Pooled it
- Devices and pressure sources for administration of nasal continuous positive airway pressure (NCPAP) in preterm neonates.The Cochrane database of systematic reviews · 2008Pooled it
- Does helmet CPAP reduce cerebral blood flow and volume by comparison with Infant Flow driver CPAP in preterm neonates?Intensive care medicine · 2006Trial
- Bubble devices versus other pressure sources for nasal continuous positive airway pressure in preterm infants.The Cochrane database of systematic reviews · 2023Review
- The use of head helmets to deliver noninvasive ventilatory support: a comprehensive review of technical aspects and clinical findings.Critical care (London, England) · 2021Review
- Hydrocolloid dressing in preventing nasal trauma secondary to nasal continuous positive airway pressure in preterm infants.World journal of emergency medicine · 2014Article
- CPAP review.European journal of pediatrics · 2012Review
- Year in review in intensive care medicine, 2005. III. Nutrition, pediatric and neonatal critical care, and experimental.Intensive care medicine · 2006Review
- Comment on "A new device for administration of continuous positive airway pressure in preterm infants" by Trevisanuto et al.Intensive care medicine · 2005Article
- Effect of Filters on the Noise Generated by Continuous Positive Airway Pressure Delivered via a Helmet.Noise & healthArticle
Corrections and comments
- Commented on by
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveWe compared the effectiveness of a new continuous positive airway pressure (CPAP) device (neonatal helmet CPAP) with a conventional nasal CPAP system in preterm neonates needing continuous distending pressure. DESIGN AND
settingRandomized, physiological, cross-over study in a tertiary referral, neonatal intensive care unit in a university teaching hospital. PATIENTS: Twenty very low birth weight infants with a postnatal age greater than 24 h who were receiving nasal CPAP for apnea and/or mild respiratory distress were enrolled.
interventionsCPAP delivered by neonatal helmet CPAP and nasal CPAP in random order for two subsequent 90-min periods. MEASUREMENTS AND
resultsWere continuously measured the Neonatal Infant Pain Scale (NIPS) score, oxygen requirements, respiratory rate, heart rate, oxygen saturation, transcutaneous PO(2) (tcPO(2)) and PCO(2) (tcPCO(2)), blood pressure, and desaturations. NIPS scores were significantly lower when the infants were on the neonatal helmet CPAP than when they were on nasal CPAP (0.26+/-0.07 vs. 0.63+/-0.12). The other studied parameters did not differ between the two CPAP modes. The number of desaturations was reduced during the neonatal helmet CPAP treatment (18 vs. 32), although this difference was not significant.
conclusionsIn this short-term physiological study the neonatal helmet CPAP appears to be as good as the golden standard for managing preterm infants needing continuous distending pressure, with enhanced tolerability. Further evaluation in a randomized clinical trial is needed to confirm these findings.