Evidence map›Paper›PMID 15653735›Full record

ArticleBiophysical journal2005

Nano- to microscale dynamics of P-selectin detachment from leukocyte interfaces. II. Tether flow terminated by P-selectin dissociation from PSGL-1.

Volkmar Heinrich, Andrew Leung, Evan Evans

Abstract read
In one paragraph

Article in Biophysical journal, 2005. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 40 papers.

0numbers the graph read from it
0cells of the map it votes in
40citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

40 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Inside-out regulation of E-cadherin conformation and adhesion.Proceedings of the National Academy of Sciences of the United States of America · 2021
    Article
  8. Article
  9. Biomechanics of Neutrophil Tethers.Life (Basel, Switzerland) · 2021
    Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Measuring forces at the leading edge: a force assay for cell motility.Integrative biology : quantitative biosciences from nano to macro · 2013
    Article
  18. Article
  19. Article
  20. Molecular structure of membrane tethers.Biophysical journal · 2012
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Volkmar HeinrichDepartment of Biomedical Engineering, Boston University, Boston, Massachusetts 02215 USA.
Andrew Leung
Evan Evans

Funding

RHEOLOGICAL AND ADHERENCE PROPERTIES OF SICKLE CELLSR01HL031579 · NHLBI · UNIVERSITY OF CALIFORNIA SAN FRANCISCO · PI NARLA, MOHANDAS · 1985 to 2010
$3.8M
DYNAMIC STRENGTHS OF SINGLE LEUKOCYTE ADHESION BONDSR01HL065333 · NHLBI · BOSTON UNIVERSITY (CHARLES RIVER CAMPUS) · PI EVANS, EVAN A · 2001 to 2011
$3.0M
NHLBI NIH HHS HL31579NHLBI NIH HHS HL65333NHLBI NIH HHS R01 HL031579NHLBI NIH HHS R01 HL065333
6 · The paper itself

Abstract

We have used a biomembrane force probe decorated with P-selectin to form point attachments with PSGL-1 receptors on a human neutrophil (PMN) in a calcium-containing medium and then to quantify the forces experienced by the attachment during retraction of the PMN at fixed speed. From first touch to final detachment, the typical force history exhibited the following sequence of events: i), an initial linear-elastic displacement of the PMN surface, ii), an abrupt crossover to viscoplastic flow that signaled membrane separation from the interior cytoskeleton and the beginning of a membrane tether, and iii), the final detachment from the probe tip most often by one precipitous step of P-selectin:PSGL-1 dissociation. Analyzing the initial elastic response and membrane unbinding from the cytoskeleton in our companion article I, we focus in this article on the regime of tether extrusion that nearly always occurred before release of the extracellular adhesion bond at pulling speeds > or =1 microm/s. The force during tether growth appeared to approach a plateau at long times. Examined over a large range of pulling speeds up to 150 microm/s, the plateau force exhibited a significant shear thinning as indicated by a weak power-law dependence on pulling speed, f(infinity) = 60 pN(nu(pull)/microm/s)(0.25). Using this shear-thinning response to describe the viscous element in a nonlinear Maxwell-like fluid model, we show that a weak serial-elastic component with a stiffness of approximately 0.07 pN/nm provides good agreement with the time course of the tether force approach to the plateau under constant pulling speed.

Indexed as

Molecular Probe TechniquesBlood Flow VelocityCell AdhesionCell Culture TechniquesCells, CulturedComputer SimulationHumansLeukocytesMembrane GlycoproteinsMicromanipulationModels, CardiovascularNanotechnologyPhysical StimulationProtein BindingP-SelectinStress, MechanicalMembrane GlycoproteinsP-SelectinP-selectin ligand protein

Identifiers

PMID15653735
PMCPMC1305279

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.