Evidence map›Paper›PMID 15526187›Full record

ArticleIntensive care medicine2005

Plasma volume measurement in septic patients using an albumin dilution technique: comparison with the standard radio-labelled albumin method.

Michael P Margarson, Neil C Soni

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Intensive care medicine, 2005. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 43 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Beyond the fluid bolus.Journal of thoracic disease · 2019
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. A novel method for blood volume estimation using trivalent chromium in rabbit models.Indian journal of plastic surgery : official publication of the Association of Plastic Surgeons of India · 2014
    Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Michael P MargarsonMagill Department of Anaesthesia, Chelsea and Westminster Hospital, 369 Fulham Road, London, SW10 3NH, UK. m.margarson@ic.ac.uk
Neil C Soni
Chelsea and Westminster Hospital · GBSt Richard's Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo investigate a technique using 20% albumin for measurement of plasma volume in critically ill patients. DESIGN AND

settingLaboratory and clinical investigation in the adult intensive care unit and anaesthetic laboratories of a university hospital. PATIENTS: 12 patients fulfilling ACCP/SCCM criteria for septic shock. INTERVENTIONS AND MEASUREMENTS: Each patient received (125)I-labelled albumin, and the volume of distribution was measured at 1 and 10 min. The accepted standard plasma volume measurement (98% of the 10-min volume of distribution) was calculated. Immediately thereafter 200 ml 20% human albumin was given. Albumin concentrations were measured before and 1 min after this 40-g bolus, and the volume of distribution calculated using a formula that corrected for the 200 ml fluid in which the albumin was dissolved.

resultsPlasma volumes measured using the albumin dilution technique at 1 min were smaller than the standard technique by 110+/-280 ml; limits of agreement were from -660 to +440 ml (-16% to +11%). Plasma volumes measured by (125)I-albumin at 1 min were smaller than the standard by 120+/-110 ml; limits of agreement were from -330 to +100 ml (-8 to +2%).

conclusionsNon-labelled albumin can be used easily and quickly to measure a plasma volume in ICU patients and gives a moderately accurate estimate when compared with the (125)I-labelled albumin methods. The normal isotope method over-estimates plasma volumes in septic patients because excessive transcapillary escape of albumin is inadequately compensated for by the standard correction factor.

Indexed as

AlbuminsCritical IllnessPlasma VolumeSerum Albumin, Radio-IodinatedBlood Volume DeterminationFemaleHumansIndicator Dilution TechniquesMaleMiddle AgedShock, SepticAlbuminsSerum Albumin, Radio-Iodinated

Identifiers

PMID15526187
OpenAlexW2087904863

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked