ReviewJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology
Cardiac neurotransmission SPECT imaging.
Review in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
30 citing papers in PubMed.
- Cardiac sympathetic activity pre and post resynchronization therapy evaluated by 123I-MIBG myocardial scintigraphy.Journal of nuclear cardiology : official publication of the American Society of Nuclear CardiologyTrial
- Dual-Mode Tumor Imaging Using Probes That Are Responsive to Hypoxia-Induced Pathological Conditions.Biosensors · 2022Review
- Anthracycline-induced cardiotoxicity: Is there a role for myocardialJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020Article
- Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020Article
- CSI position statement on management of heart failure in India.Indian heart journal · 2018Review
- New horizons in cardiac innervation imaging: introduction of novelEuropean journal of nuclear medicine and molecular imaging · 2017Review
- Optimization of a simultaneous dual-isotopeJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2017Article
- Current Clinical Applications and Next Steps for Cardiac Innervation Imaging.Current cardiology reports · 2017Review
- ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016Article
- Recent trends in nuclear cardiology practice.Chonnam medical journal · 2013Review
- Influence of myocardial region of interest definition on quantitative analysis of planar 123I-mIBG images.European journal of nuclear medicine and molecular imaging · 2013Article
- PET and SPECT in heart failure.Current cardiology reports · 2013Review
- Cardiac autonomic imaging with SPECT tracers.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2013Review
- Assessment of global cardiac I-123 MIBG uptake and washout using volumetric quantification of SPECT acquisitions.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2012Article
- Use of cardiac radionuclide imaging to identify patients at risk for arrhythmic sudden cardiac death.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2012Review
- Understanding the genetics of coronary artery disease through the lens of noninvasive imaging.Expert review of cardiovascular therapy · 2012Review
- Myocardial perfusion scintigraphy: past, present and future.The British journal of radiology · 2011Review
- The role of nuclear imaging in the failing heart: myocardial blood flow, sympathetic innervation, and future applications.Heart failure reviews · 2011Review
- Variation of heart-to-mediastinal ratio in (123)I-mIBG cardiac sympathetic imaging: its affecting factors and potential corrections.Current cardiology reports · 2011Review
- Radionuclide imaging of cardiac autonomic innervation.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2010Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The sympathetic nervous system has great influence on cardiovascular physiology. Cardiac neurotransmission single photon emission computed tomography (SPECT) imaging allows in vivo noninvasive assessment of presynaptic reuptake and storage of neurotransmitters, which offers characterization of the cardiac neuronal function in different diseases of the heart and other altered metabolic or functional conditions. Therefore assessment of the integrity of cardiac sympathetic innervation may help in the diagnosis of these disorders, as well as in prognostication, and will result in better therapy and outcome. At present, the most widely available SPECT tracer by which to assess cardiac neurotransmission is metaiodobenzylguanidine labeled with iodine 123. This article focuses on reviewing the characteristics of cardiac SPECT imaging with I-123 metaiodobenzylguanidine and its role in the assessment of pathophysiologic changes during relevant clinical conditions.
Indexed as
Identifiers
15472644What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.