Evidence map›Paper›PMID 15338737›Full record

Trial reportIEEE transactions on medical imaging2004

Respiratory motion of the heart from free breathing coronary angiograms.

Guy Shechter, Cengizhan Ozturk, Jon R Resar, Elliot R McVeigh

Open access · greenAbstract readClinical TrialComparative StudyValidation Study
In one paragraph

Trial report in IEEE transactions on medical imaging, 2004. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 46 papers.

0numbers the graph read from it
0cells of the map it votes in
46citing papers in PubMed
4.9field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

46 citing papers in PubMed, 149 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Observational
  5. Multifunctional bioelectronics for brain-body circuits.Nature reviews bioengineering · 2025
    Article
  6. Article
  7. Highly efficient free-breathing 3D whole-heart imaging in 3-min: single center study in adults with congenital heart disease.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2024
    Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2021
    Review
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Guy ShechterLaboratory of Cardiac Energetics, NHLBI, National Institutes of Health, DHHS, Bethesda, MD 20892, USA. guy@jhu.edu
Cengizhan Ozturk
Jon R Resar
Elliot R McVeigh
National Institutes of Health · USJohns Hopkins University · US

Funding

ULTRA FAST MRI FOR CARDIOVASCULAR APPLICATIONSZ01HL004608 · NHLBI · HEART, LUNG, AND BLOOD INSTITUTE · PI MCVEIGH, ELLIOT R · 2000 to 2006
–
HIGH RESOLUTION ELECTROMECHANICAL MAPPING OF THE HEARTZ01HL004609 · NHLBI · HEART, LUNG, AND BLOOD INSTITUTE · PI MCVEIGH, ELLIOT R · 2000 to 2006
–
Intramural NIH HHS Z01 HL004608
6 · The paper itself

Abstract

Respiratory motion compensation for cardiac imaging requires knowledge of the heart's motion and deformation during breathing. This paper presents a method for measuring the natural tidal respiratory motion of the heart from free breathing coronary angiograms. A three-dimensional (3-D) deformation field describing the cardiac and respiratory motion of the coronary arteries is recovered from a biplane acquisition. A cardiac respiratory parametric model is formulated and used to decompose the deformation field into cardiac and respiratory components. Angiograms from ten patients were analyzed. A 3-D translation motion model was sufficient for describing the motion of the heart in only two patients. For all patients, the heart translated caudally (mean, 4.9+/-1.9 mm; range, 2.4 to 8.0 mm) and underwent a cranio-dorsal rotation (mean, 1.5 degrees+/-0.9 degrees; range, 0.2 degrees to 3.5 degrees) during inspiration. In eight patients, the heart also translated anteriorly (mean, 1.3+/-1.8 mm; range, -0.4 to 5.1 mm) and rotated in a caudo-dextral direction (mean, 1.2 degrees+/-1.3 degrees; range, -1.9 degrees to 3.2 degrees).

Indexed as

MovementRespirationRespiratory MechanicsAgedAlgorithmsArtifactsCardiomegalyCardiomyopathy, DilatedCoronary AngiographyFemaleHeartHumansImaging, Three-DimensionalMaleRadiographic Image EnhancementRadiographic Image Interpretation, Computer-Assisted

Identifiers

PMID15338737
PMCPMC2494710
OpenAlexW2112129912

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.