ArticleBritish journal of anaesthesia2004
Block-dependent sedation during epidural anaesthesia is associated with delayed brainstem conduction.
Article in British journal of anaesthesia, 2004. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Neostigmine decreases bupivacaine use by patient-controlled epidural analgesia during labor: a randomized controlled study.Anesthesia and analgesia · 2009Trial
- Movements During Intended General Anesthesia and Psychologically Traumatic Accidental Awareness: Explanatory Role of the "Efference Copy Network".Anesthesia and analgesia · 2026Article
- Electroencephalographic assessment of infant spinal anesthesia: A pilot prospective observational study.Paediatric anaesthesia · 2021Observational
- Dose Comparison of Dexmedetomidine Sedation following Spinal Anesthesia: Parturient versus Nonpregnant Women-A Randomized Trial.Anesthesiology research and practice · 2020Article
- Effects of intrathecal bupivacaine on the NR2B/CaMKIIα/CREB signaling pathway in the rat lumbar spinal cord.Molecular medicine reports · 2018Article
- Transient Coma Due To Epidural Anesthesia: The Role of Loss of Sensory Input.The American journal of case reports · 2015Article
- Caudal analgesia reduces the sevoflurane requirement for LMA removal in anesthetized children.Korean journal of anesthesiology · 2010Article
- Using EEG to monitor anesthesia drug effects during surgery.Journal of clinical monitoring and computing · 2006Review
- A study of the effect of caudal epidural block on bispectral index targeted propofol requirement in children: A comparative study.Journal of Indian Association of Pediatric SurgeonsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
backgroundNeuraxial anaesthesia produces a sedative and anaesthetic-sparing effect. Recent evidence suggests that spinal cord anaesthesia modifies reticulo-thalamo-cortical arousal by decreasing afferent sensory transmission. We hypothesized that epidural anaesthesia produces sensory deafferentation-dependent sedation that is associated with impairment of brainstem transmission. We used brainstem auditory evoked potentials (BAEP) to evaluate reticular function in 11 volunteers.
methodsEpidural anaesthesia was induced with 2-chloroprocaine 2%. Haemodynamic and respiratory responses, sensory block level, sedation depth and BAEP were assessed throughout induction and resolution of epidural anaesthesia. Sedation was evaluated using verbal rating score (VRS), observer's assessment alertness/sedation (OAA/S) score, and bispectral index score (BIS). Prediction probability (PK) was used to associate sensory block with sedation, as well as BIS with other sedation measures. Spearman's rank order correlation was used to associate block level and sedation with the absolute and interpeak BAEP latencies.
resultsSensory block level significantly predicted VRS (PK=0.747), OAA/S score (PK=0.748) and BIS. BIS predicted VRS and OAA/S score (PK=0.728). The latency of wave III of BAEP significantly correlated with sedation level (rho=0.335, P<0.01) and sensory block (rho=0.394, P<0.01). The other BAEP parameters did not change during epidural anaesthesia. Haemodynamic and respiratory responses remained stable throughout the study.
conclusionsSedation during epidural anaesthesia depends on sensory block level and is associated with detectable block-dependent alterations in the brainstem auditory evoked responses. Sensory deafferentation may reduce CNS alertness through mechanisms related to brainstem neural activity.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.