Trial reportThorax2004
Failure of sputum eosinophilia after eotaxin inhalation in asthma.
Trial report in Thorax, 2004. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 5 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundEotaxin is a chemokine specific for eosinophils and may play an important role in eosinophil recruitment in asthma. The effects of eotaxin inhalation on sputum and blood eosinophils, exhaled nitric oxide (NO), and bronchial responsiveness were determined.
methodsEotaxin was administered by nebulisation to asthma patients in three studies: (1) an open dose finding study with eotaxin (5, 10 and 20 microg) to two asthmatic subjects; (2) a randomised placebo controlled study with 20 microg eotaxin to five asthmatic subjects and five normal volunteers; and (3) a randomised placebo controlled study with 40 microg eotaxin to nine asthmatics. Forced expiratory volume in 1 second (FEV(1)), exhaled NO, and blood eosinophils were measured before and hourly for 5 hours after nebulisation and at 24 and 72 hours. Methacholine bronchial challenge and sputum induction were performed before and at 5, 24, and 72 hours after nebulisation.
resultsIn the two placebo controlled studies there was no change in sputum eosinophil count and sputum eosinophilic cationic protein concentration after eotaxin inhalation compared with placebo. FEV(1), exhaled NO, and methacholine PC(20) did not change. However, high dose eotaxin (40 microg) induced an increase in sputum neutrophil count compared with placebo (p<0.05).
conclusionsInhaled eotaxin up to 40 microg induced no changes in sputum eosinophil count but at 40 microg it increased the sputum neutrophil count. The significance of this finding is unknown.