ArticleHuman brain mapping2004
Multimodal integration of EEG and MEG data: a simulation study with variable signal-to-noise ratio and number of sensors.
Article in Human brain mapping, 2004. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 53 citations in OpenAlex.
- The evolution of a disparity decision in human visual cortex.NeuroImage · 2014Trial
- Volumetric mesoscopic electrophysiology: a new imaging modality for the nonhuman primate.Journal of neurophysiology · 2025Article
- Article
- Wearable neuroimaging: Combining and contrasting magnetoencephalography and electroencephalography.NeuroImage · 2019Article
- A Time-Varying Connectivity Analysis from Distributed EEG Sources: A Simulation Study.Brain topography · 2018Article
- Reproducibility of EEG-MEG fusion source analysis of interictal spikes: Relevance in presurgical evaluation of epilepsy.Human brain mapping · 2018Article
- Noninvasive Electromagnetic Source Imaging and Granger Causality Analysis: An Electrophysiological Connectome (eConnectome) Approach.IEEE transactions on bio-medical engineering · 2016Article
- Effects of reconstructed magnetic field from sparse noisy boundary measurements on localization of active neural source.Medical & biological engineering & computing · 2016Article
- How to use fMRI functional localizers to improve EEG/MEG source estimation.Journal of neuroscience methods · 2015Review
- A multi-subject, multi-modal human neuroimaging dataset.Scientific data · 2015Article
- EEG-MEG Integration Enhances the Characterization of Functional and Effective Connectivity in the Resting State Network.PloS one · 2015Article
- Beamformer source analysis and connectivity on concurrent EEG and MEG data during voluntary movements.PloS one · 2014Article
- Adaptive cluster analysis approach for functional localization using magnetoencephalography.Frontiers in neuroscience · 2013Article
- Increasing the accuracy of electromagnetic inverses using functional area source correlation constraints.Human brain mapping · 2012Article
- Article
- Estimation of effective and functional cortical connectivity from neuroelectric and hemodynamic recordings.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2009Article
- Mapping the signal-to-noise-ratios of cortical sources in magnetoencephalography and electroencephalography.Human brain mapping · 2009Article
- A novel integrated MEG and EEG analysis method for dipolar sources.NeuroImage · 2007Article
- Comparison of different cortical connectivity estimators for high-resolution EEG recordings.Human brain mapping · 2007Article
- Motor-related cortical dynamics to intact movements in tetraplegics as revealed by high-resolution EEG.Human brain mapping · 2006Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Previous simulation studies have stressed the importance of the multimodal integration of electroencephalography (EEG) and magnetoencephalography (MEG) data in the estimation of cortical current density. In such studies, no systematic variations of the signal-to-noise ratio (SNR) and of the number of sensors were explicitly taken into account in the estimation process. We investigated effects of variable SNR and number of sensors on the accuracy of current density estimate by using multimodal EEG and MEG data. This was done by using as the dependent variable both the correlation coefficient (CC) and the relative error (RE) between imposed and estimated waveforms at the level of cortical region of interests (ROI). A realistic head and cortical surface model was used. Factors used in the simulations were: (1). the SNR of the simulated scalp data (with seven levels: infinite, 30, 20, 10, 5, 3, 1); (2). the particular inverse operator used to estimate the cortical source activity from the simulated scalp data (INVERSE, with two levels, including minimum norm and weighted minimum norm); and (3). the number of EEG or MEG sensors employed in the analysis (SENSORS, with three levels: 128, 61, 29 for EEG and 153, 61, or 38 in MEG). Analysis of variance demonstrated that all the considered factors significantly affect the CC and the RE indexes. Combined EEG-MEG data produced statistically significant lower RE and higher CC in source current density reconstructions compared to that estimated by the EEG and MEG data considered separately. These observations hold for the range of SNR values presented by the analyzed data. The superiority of current density estimation by multimodal integration of EEG and MEG was not due to differences in number of sensors between unimodal (EEG, MEG) and combined (EEG-MEG) inverse estimates. In fact, the current density estimate relative to the EEG-MEG multimodal integration involved 61 EEG plus 63 MEG sensors, whereas estimations carried out with the single modalities alone involved 128 sensors for EEG and 153 sensors for MEG. The results of the simulations also suggest that the use of simultaneous 29 EEG sensors during the MEG measurements carried out with full sensor arrangements (153 sensors) returned an accuracy of the cortical source estimate statistically similar to that obtained by combining 64 EEG and 153 MEG sensors.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.