Evidence map›Paper›PMID 14583909›Full record

SynthesisThe Cochrane database of systematic reviews2003

Elective high frequency oscillatory ventilation versus conventional ventilation for acute pulmonary dysfunction in preterm infants.

D J Henderson-Smart, T Bhuta, F Cools, M Offringa

Abstract readMeta-AnalysisSystematic Review
PubMed Publisher
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2003. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 5 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 5 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 5 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. The clinical impact of high frequency ventilation: review of the Cochrane meta-analyses.Journal of perinatology : official journal of the California Perinatal Association · 2006
    Pooled it
  4. Pooled it
  5. Pooled it
  6. Trial
  7. Review
  8. Article
  9. Bias flow does not affect ventilation during high-frequency oscillatory ventilation in a pediatric animal model of acute lung injury.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2012
    Article
  10. Can we improve outcome of congenital diaphragmatic hernia?Pediatric surgery international · 2009
    Review
  11. Predictors of death or bronchopulmonary dysplasia in preterm infants with respiratory failure.Journal of perinatology : official journal of the California Perinatal Association · 2008
    Article
  12. Article
  13. How has research in the past 5 years changed my clinical practice.Archives of disease in childhood. Fetal and neonatal edition · 2007
    Review
  14. Malposition of endotracheal tube: association with pneumothorax in ventilated neonates.Archives of disease in childhood. Fetal and neonatal edition · 2007
    Article
  15. Article
  16. Review
  17. Respiratory complications of preterm birth.BMJ (Clinical research ed.) · 2004
    Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

4 authors.

D J Henderson-SmartNSW Centre for Perinatal Health Services Research, Queen Elizabeth II Institute for Mothers and Infants, Building DO2, University of Sydney, Sydney, NSW, Australia, 2006. dhs@perinatal.usyd.edu.au
T Bhuta
F Cools
M Offringa

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRespiratory failure due to lung immaturity is a major cause of mortality in preterm infants. Although intermittent positive pressure ventilation (IPPV) saves lives, lung distortion during its use is associated with lung injury and chronic lung disease (CLD). Conventional IPPV is provided at 30-80 breaths per minute while a newer form of ventilation called high frequency oscillatory ventilation (HFOV) provides 'breaths' at 10-15 cycles per second. This has been shown to result in less lung injury in experimental studies.

objectivesThe objective of this review is to determine whether the elective use of high frequency oscillatory ventilation as compared to conventional ventilation (CV) in preterm infants who are mechanically ventilated for the respiratory distress syndrome decreases the incidence of chronic lung disease, without adverse effects. SEARCH STRATEGY: Searches were made of the Oxford Database of Perinatal Trials, MEDLINE, EMBASE, previous reviews including cross references, abstracts, conferences and symposia proceedings, expert informants, journal hand searching by the Cochrane Collaboration, mainly in the English language. The search was updated in May 2003. SELECTION CRITERIA: Randomized controlled trials comparing HFOV and CV in preterm or low birth weight infants with pulmonary dysfunction, mainly due to RDS, who are to be given IPPV. Randomization and commencement of treatment should have been as soon as possible after the start of IPPV and usually in the first 12 hours of life. DATA COLLECTION AND ANALYSIS: The methodological quality of each trial was independently reviewed by the various authors. Each author extracted data separately; they were compared and differences were resolved. Treatment effects were expressed using relative risk (RR) and risk difference (RD). From 1/RD the number needed to treat (NNT) to produce one outcome were calculated. Ninety five percent confidence intervals were used for all measures of effect. MAIN

resultsEleven eligible studies on 3,275 infants were included. Meta-analysis comparing HFOV with CV revealed no evidence of effect on mortality at 28-30 days of age or at approximately term equivalent age. These results were consistent across studies. The effect of HFOV on CLD in survivors at term equivalent GA was inconsistent across studies and not significant overall. Pre-specified subgroup analyses according to use of a high volume strategy, or use of surfactant, did not identify subgroups in which there was evidence of effect on death, or in which the size of effect on CLD was substantially increased, or in which heterogeneity of treatment effect on CLD was removed. Short term neurological morbidity caused by HFOV was found in some studies, but this effect was not statistically significant overall. The subgroup of two trials not using a high volume strategy with HFOV found increased rates of Grade 3 or 4 IVH and of periventricular leukomalacia. An adverse effect of HFOV on longer term neurodevelopment was found in one large trial but not in two other small trials which reported this outcome. REVIEWER'S

conclusionsThere is no clear evidence from this systematic review that elective HFOV, as compared with CV, offers important advantages when used as the initial ventilation strategy to treat preterm babies with acute pulmonary dysfunction. There is no evidence of a reduction in death rate. There may be a small reduction in the rate of CLD with HFOV use but the evidence is weakened by the inconsistency of this effect across trials and is not significant overall. Adverse effects on short term neurological outcomes have been observed in some studies but these effects are not significant overall. Information about effects on long term outcome is not adequate overall. Any future trials on elective HFOV should target those infants who are at most risk of CLD (extremely preterm), compare different strategies for generating HFOV and CV, and report important long term pulmonary and neurodevelopmental outcomes. Economic analysis should also be incorporated.

Indexed as

High-Frequency VentilationIntermittent Positive-Pressure VentilationChronic DiseaseHumansInfant, NewbornInfant, PrematureInfant, Premature, DiseasesLung DiseasesRandomized Controlled Trials as TopicRespiratory Distress Syndrome, Newborn

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.