Evidence map›Paper›PMID 12736836›Full record

Trial reportEuropean journal of applied physiology2003

Maximal lactate steady state, respiratory compensation threshold and critical power.

J Dekerle, B Baron, L Dupont, J Vanvelcenaher, P Pelayo

Registry-linked trialAbstract readClinical TrialComparative Study
PubMed Publisher
In one paragraph

Trial report in European journal of applied physiology, 2003. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04732611 (Effects of Pilates Exercises Versus Walking on Mechanical and Vascular Variables of Individuals With Type 2 Diabetes Mellitus), which is not on this map. Cited by 61 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
61citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04732611 naunknown statusnot on this mapstarted 2021, after this paper: background citation

Effects of Pilates Exercises Versus Walking on Mechanical and Vascular Variables of Individuals With Type 2 Diabetes Mellitus: Randomized Clinical Trial

TypeinterventionalSponsorFederal University of Rio Grande do SulRan2021 to 2022Enrolled60ConditionsDiabetes Mellitus, Type 2ArmsPilates exercises, Walking protocol
3 · Its place in the literature

Who cites it

61 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Chronobiological Effects on Mountain Biking Performance.International journal of environmental research and public health · 2020
    Trial
  5. Trial
  6. Trial
  7. Trial
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Review
  19. Review
  20. Article

1 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

J DekerleLaboratoire d'Etudes de la Motricité Humaine, Faculté des Sciences du Sport et de l'EP, Lille 2, 9 rue de l'Université, 59790 Ronchin, France.
B Baron
L Dupont
J Vanvelcenaher
P Pelayo

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Critical power (CP) and the second ventilatory threshold (VT(2)) are presumed to indicate the power corresponding to maximal lactate steady state (MLSS). The aim of this study was to investigate the use of CP and VT(2) as indicators of MLSS. Eleven male trained subjects [mean (SD) age 23 (2.9) years] performed an incremental test (25 W.min(-1)) to determine maximal oxygen uptake (.VO(2max)), maximal aerobic power (MAP) and the first and second ventilatory thresholds (VT(1) and VT(2)) associated with break points in minute ventilation (.V(E)), carbon dioxide production (.VCO(2)), .V(E)/.VCO(2) and .V(E)/.VO(2) relationships. Exhaustion tests at 90%, 95%, 100% and 110% of .VO(2max), and several 30-min constant work rates were performed in order to determine CP and MLSS, respectively. MAP and .VO(2max) values were 344 (29) W and 53.4 (3.7) ml.min(-1).kg(-1), respectively. CP [278 (22) W; 85.4 (4.8)% .VO(2max)] and VT(2) power output [286 (28) W; 85.3 (5.6)% .VO(2max)] were not significantly different (p=0.96) but were higher (p<0.05) than the MLSS work rate [239 (21) W; 74.3 (4.0)% .VO(2max)] and VT(1) power output [159 (23) W; 52.9 (6.9)% .VO(2max)]. MLSS work rate was significantly correlated (p<0.05) with those noted at VT(1) and VT(2) (r=0.74 and r=0.93, respectively). VT(2) overestimated MLSS by 10.9 (6.3)% .VO(2max), which was significantly higher than VT(1) [+21.4 (5.6)% .VO(2max); p<0.01]. CP calculated from a given range of exhaustion times does not correspond to MLSS.

Indexed as

Adaptation, PhysiologicalAdultAnaerobic ThresholdBicyclingEnergy TransferExerciseExercise TestHomeostasisHumansLactic AcidMaleMuscle, SkeletalOxygen ConsumptionPhysical EnduranceRespiratory MechanicsLactic Acid

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.