Evidence map›Paper›PMID 12677300›Full record

ArticleEuropean journal of nuclear medicine and molecular imaging2003

Comparative value of ECG-gated blood pool SPET and ECG-gated myocardial perfusion SPET in the assessment of global systolic left ventricular function.

Doumit Daou, Didier Vilain, Patrice Colin, Rachida Lebtahi, Thierry Fourme, Carlos Coaguila, Abdel Benada, Ilana Idy-Peretti, Michel Slama, Dominique Le Guludec

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2003. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. SPECT radionuclide angiography: it is time for a consensus statement.European journal of nuclear medicine and molecular imaging · 2007
    Review
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

10 authors.

Doumit DaouDepartment of Nuclear Medicine, Lariboisière University Hospital, AP-HP, Paris, France. doumit.daou@lrb.ap-hop-paris.fr
Didier Vilain
Patrice Colin
Rachida Lebtahi
Thierry Fourme
Carlos Coaguila
Abdel Benada
Ilana Idy-Peretti
Michel Slama
Dominique Le Guludec

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Both electrocardiographically (ECG) gated blood pool SPET (GBPS) and ECG-gated myocardial perfusion SPET (GSPET) are currently used for the measurement of global systolic left ventricular (LV) function. In this study, we aimed to compare the value of GSPET and GBPS for this purpose. The population included 65 patients who underwent rest thallium-201 GSPET imaging at 15 min after (201)Tl injection followed by planar (planar(RNA)) and GBPS equilibrium radionuclide angiography immediately after 4-h redistribution myocardial perfusion SPET imaging. Thirty-five patients also underwent LV conventional contrast angiography (X-rays). LV ejection fraction (EF) and LV volume [end-diastolic (EDV) and end-systolic (ESV) volumes] were calculated with GBPS and GSPET and compared with the gold standard methods (planar(RNA) LVEF and X-ray based calculation of LV volume). For both LVEF and LV volume, the inter-observer variability was lower with GBPS than with GSPET. GBPS LVEF was higher than planar(RNA) (P<0.01) and GSPET LVEF (P<0.01). Planar(RNA) LVEF showed a slightly better correlation with GBPS LVEF than with GSPET LVEF: r=0.87 and r=0.83 respectively. GSPET LV volume was lower than that obtained using X-rays and GBPS (P<0.01 for both). LV volume calculated using X-rays showed a slightly better correlation with GBPS LV volume than with GSPET LV volume: r=0.88 and r=0.83 respectively. On stepwise regression analysis, the accuracy of GSPET for the measurement of LVEF and LV volume was correlated with a number of factors, including planar(RNA) LVEF, signal to noise ratio, LV volume calculated using X-rays, summed rest score and acquisition scan distance (i.e. the radius of rotation). The accuracy of GBPS for the measurement of LVEF and LV volume was correlated only with the signal level, the signal to noise ratio and the acquisition scan distance. Both GSPET and GBPS provide reliable estimation of global systolic LV function. The better reliability of GBPS and in particular its lower sensitivity to different variables as compared with GSPET favours its use when precise assessment of global systolic LV function is clinically indicated.

Indexed as

AdultAgedAged, 80 and overBiological TransportCoronary DiseaseCoronary VesselsElectrocardiographyFemaleGated Blood-Pool ImagingHumansMaleMiddle AgedMyocardial InfarctionRadiopharmaceuticalsRegression AnalysisReproducibility of ResultsRadiopharmaceuticalsTechnetium

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.