SynthesisThe Cochrane database of systematic reviews2003
Techniques for the interruption of tubal patency for female sterilisation.
Synthesis in The Cochrane database of systematic reviews, 2003. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Techniques for the interruption of tubal patency for female sterilisation.The Cochrane database of systematic reviews · 2016Pooled it
- Socioeconomic disparities in ectopic pregnancy: predictors of adverse outcomes from Illinois hospital-based care, 2000-2006.Maternal and child health journal · 2011Article
- Training of residents in laparoscopic tubal sterilization: long-term failure rates.The European journal of contraception & reproductive health care : the official journal of the European Society of Contraception · 2008Article
Corrections and comments
- Updated by
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundFemale sterilization is the most popular contraceptive method worldwide. Several techniques are described in the literature, however only few of them are commonly used and properly evaluated.
objectivesTo compare the different tubal occlusion techniques in terms of major and minor morbidity, failure rates (pregnancies), technical failures and difficulties and women's and surgeons' views. SEARCH STRATEGY: The Cochrane Controlled Trials Register has been searched. A search of the reference lists of identified trials was performed. An additional MEDLINE search was done using an Internet search service Pub Med. SELECTION CRITERIA: All randomized controlled trials comparing different techniques for tubal sterilization, regardless of the way of entry in the abdominal cavity or the method of anesthesia. DATA COLLECTION AND ANALYSIS: Trials under consideration were evaluated for methodological quality and appropriateness for inclusion. Nine relevant studies were included and the results were stratified in five groups: tubal ring versus clip, modified Pomeroy versus electrocoagulation, tubal ring versus electrocoagulation, modified Pomeroy versus Filshie clip and Hulka versus Filshie clip. Results are reported as odds ratio for dichotomous outcomes and weighted mean differences for continuous outcomes. MAIN
resultsTubal ring versus clip: Minor morbidity was higher in the ring group (Peto OR 2.15; 95% CI 1.22, 3.78). Technical difficulties were found less frequent in the clip group ( Peto OR 3.87; 95% CI 1.90, 7.89). There was no difference in failure rates between the two groups (Peto OR 0.70; 95% CI 0.28, 1.76). Pomeroy versus electrocoagulation: Women undergoing modified Pomeroy technique had higher major morbidity than with electrocoagulation technique (Peto OR 2.87; 95% CI 1.13, 7.25). Postoperative pain was more frequent in the Pomeroy group (Peto OR 3.85; 95% CI 2.91, 5.10). Tubal ring versus electrocoagulation: Post operative pain was more frequently reported in the tubal ring group. No pregnancies were reported. Pomeroy versus Filshie clip: In the trial comparing the two interventions only one pregnancy was reported in the Pomeroy group after follow-up for 24 months. No differences were found when comparing Hulka versus Filshie clip in the only study that compared these two devices (Toplis 1988). REVIEWER'S
conclusionsElectrocoagulation was associated with less morbidity when compared with tubal ring and other methods. However the risk of burns to the small bowel might be a serious criticism of the approach. The small sample size and the relative short period of follow-up in these studies limited the power to show clinical or statistical differences for rare outcomes such as failure rates. Aspects such as training, costs and maintenance of the equipment may be important factors in deciding which method to choose.
Indexed as
Identifiers
12535448What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.