ArticleBreast cancer research : BCR2002
Impact of false-positive mammography on subsequent screening attendance and risk of cancer.
Article in Breast cancer research : BCR, 2002. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 39 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
39 citing papers in PubMed, 1 synthesis or guideline pooled it, 121 citations in OpenAlex.
- Factors associated with attendance at screening for breast cancer: a systematic review and meta-analysis.BMJ open · 2021Pooled it
- False-positive results in the randomized controlled trial of mammographic screening from age 40 ("Age" trial).Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology · 2010Trial
- Multicancer Detection Assays: Promise and Potential Harms of a Novel Cancer Screening Tool.The Permanente journal · 2026Article
- Over-detection and over-surveillance in breast screening: current status and the potential for artificial intelligence optimisation.Insights into imaging · 2025Review
- Misdiagnosis in breast imaging: a statement paper from European Society Breast Imaging (EUSOBI)-Part 1: The role of common errors in radiology in missed breast cancer and implications of misdiagnosis.European radiology · 2025Review
- A multi-stage fusion framework to classify breast lesions using deep learning and radiomics features computed from four-view mammograms.Medical physics · 2023Article
- Article
- The ability of digital breast tomosynthesis to reduce additional examinations in older women.Frontiers in medicine · 2023Article
- Improving Performance of Breast Lesion Classification Using a ResNet50 Model Optimized with a Novel Attention Mechanism.Tomography (Ann Arbor, Mich.) · 2022Article
- Applying artificial intelligence technology to assist with breast cancer diagnosis and prognosis prediction.Frontiers in oncology · 2022Review
- Automatic Pectoral Muscle Removal and Microcalcification Localization in Digital Mammograms.Healthcare informatics research · 2021Article
- Subsequent attendance in a breast cancer screening program after a false-positive result in the Local Health Authority of Bologna (Italy).Scientific reports · 2021Article
- The "Sweet Spot" Revisited: Optimal Recall Rates for Cancer Detection With 2D and 3D Digital Screening Mammography in the Metro Chicago Breast Cancer Registry.AJR. American journal of roentgenology · 2021Article
- Subjective Versus Quantitative Methods of Assessing Breast Density.Diagnostics (Basel, Switzerland) · 2020Article
- Association of Microcalcification Clusters with Short-term Invasive Breast Cancer Risk and Breast Cancer Risk Factors.Scientific reports · 2019Article
- Detection of potential microcalcification clusters using multivendor for-presentation digital mammograms for short-term breast cancer risk estimation.Medical physics · 2019Review
- Long-term risk of screen-detected and interval breast cancer after false-positive results at mammography screening: joint analysis of three national cohorts.British journal of cancer · 2019Article
- Use of Breast Cancer Screening and Its Association with Later Use of Preventive Services among Medicare Beneficiaries.Radiology · 2018Article
- Observational
- Applying a new computer-aided detection scheme generated imaging marker to predict short-term breast cancer risk.Physics in medicine and biology · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundOne area of concern within the largely successful UK National Health Service breast screening programme is the relatively high proportion of women showing mammographic abnormalities who undergo further diagnostic tests that prove negative. Previous studies suggest that, in addition to increasing anxiety, such false-positive mammography is associated with increased risk of subsequent interval cancer. In the present article, we quantify this increased risk, investigate whether it extends to cancers detected at rescreening, and determine whether cancers differ between women who have, and have not, experienced false-positive mammography.
methodsThis was a retrospective cohort study of 140,387 women aged 49-63 years routinely invited for first screening by the East Anglian National Health Service breast screening programme. Proportions reattending, and subsequent risk and pathological attributes of cancer were compared between women who underwent further (negative) assessment following false-positive mammography and women mammographically normal at first screen.
resultsAt first screen, 108,617 (91.9%) of the screened women were mammographically normal, 4278 (3.6%) were assessed and then judged normal, and 514 (0.4%) underwent benign biopsy. Compared with nonassessed normal women, reattendance was lower among assessed women: 83.1% (95% confidence interval [CI], 82.0-84.1) versus 85.7% (95% CI, 85.5-85.9) (odds ratio [OR], 0.82; 95% CI, 0.76-0.89). Assessed women were at greater risk of interval cancer (rate per 1000 women screened, 9.6 [95% CI, 6.8-12.4] versus 3.0 [95% CI, 2.7-3.4]; OR, 3.19 [95% CI, 2.34-4.35]), and also of cancer detected at second screen (rate per 1000, 8.4 [95% CI, 5.8-10.9] versus 3.9 [95% CI, 3.5-4.3]; OR, 2.15 [95% CI, 1.55-2.98]). More cancers in assessed women measured >or = 20 mm (OR, 1.59; 95% CI, 0.99-2.55).
conclusionsWomen undergoing false-positive mammography at first screen were less likely to reattend for subsequent screens than were nonassessed women, yet they were more likely to develop interval cancers or cancers at second screen, and their cancers were larger. Factors predisposing for false-positive mammography require investigation. Women should be encouraged to continue with screening.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.