Trial reportJournal of clinical microbiology2001
Performance of Applied Biosystems ViroSeq HIV-1 Genotyping System for sequence-based analysis of non-subtype B human immunodeficiency virus type 1 from Uganda.
Trial report in Journal of clinical microbiology, 2001. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 54 citations in OpenAlex.
- Trial
- OLA-Simple: A software-guided HIV-1 drug resistance test for low-resource laboratories.EBioMedicine · 2019Article
- Long-Range HIV Genotyping Using Viral RNA and Proviral DNA for Analysis of HIV Drug Resistance and HIV Clustering.Journal of clinical microbiology · 2015Article
- Importance of Viral Sequence Length and Number of Variable and Informative Sites in Analysis of HIV Clustering.AIDS research and human retroviruses · 2015Article
- Performance of an in-house human immunodeficiency virus type 1 genotyping system for assessment of drug resistance in Cuba.PloS one · 2015Article
- Translational HIV-1 research: from routine diagnostics to new virology insights in Amsterdam, the Netherlands during 1983-2013.Retrovirology · 2013Review
- Comparative evaluation of the ViroSeq™ HIV-1 genotyping system and an in-house method for analysis of HIV-1 drug-resistance mutations in China.Molecular diagnosis & therapy · 2011Article
- Article
- Sensitivity and specificity of the ViroSeq human immunodeficiency virus type 1 (HIV-1) genotyping system for detection of HIV-1 drug resistance mutations by use of an ABI PRISM 3100 genetic analyzer.Journal of clinical microbiology · 2005Article
- Performance of the Celera Diagnostics ViroSeq HIV-1 Genotyping System for sequence-based analysis of diverse human immunodeficiency virus type 1 strains.Journal of clinical microbiology · 2004Article
- Performance characteristics of human immunodeficiency virus type 1 (HIV-1) genotyping systems in sequence-based analysis of subtypes other than HIV-1 subtype B.Journal of clinical microbiology · 2003Article
- Testing genotypic and phenotypic resistance in human immunodeficiency virus type 1 isolates of clade B and other clades from children failing antiretroviral therapy.Journal of clinical microbiology · 2002Article
- Genotypic testing for human immunodeficiency virus type 1 drug resistance.Clinical microbiology reviews · 2002Review
- Pitfalls of antiretroviral drug resistance genotyping of HIV-1 Group M and Group N from Cameroon by sequenced-based assays.Nigerian medical journal : journal of the Nigeria Medical AssociationArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
Abstract
The Applied Biosystems ViroSeq HIV-1 Genotyping System is a commercially available, integrated system for sequence-based analysis of drug resistance mutations in human immunodeficiency virus type 1 (HIV-1) protease and reverse transcriptase (RT). We evaluated the performance of this system for analysis of non-subtype B HIV-1 by analyzing plasma samples from Ugandan women and infants. Plasma samples were obtained from 105 women and 25 infants enrolled in a Ugandan clinical trial. HIV-1 analysis was performed with the ViroSeq system according to the manufacturer's instructions, except that the volume of plasma used for analysis was less than the recommended 0.5 ml for some samples. Viral loads ranged from 2,313 to 2,336,400 copies/ml. PCR products suitable for sequencing were amplified from all samples tested. Complete sequences for protease (amino acids 1 to 99) and RT (amino acids 1 to 320) were obtained for 102 of 105 (97%) of the maternal samples tested and all 25 of the infant samples tested. Complete double-stranded sequences were obtained for 90 of 105 (86%) of the maternal samples tested and 22 of 25 (88%) of the infant samples tested. The sequences obtained with this system were used for HIV-1 subtyping. The subtypes identified were A, C, D, and A/D recombinant HIV-1. The performances of the seven sequencing primers were similar for the subtypes examined. The ViroSeq system performs well for analysis of Ugandan plasma samples with subtypes A, C, D, and A/D recombinant HIV-1. The availability of this genotyping system should facilitate studies of HIV-1 drug resistance in countries where these subtypes are prevalent.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.