ArticleBiophysical journal2001
Nonlinear flow affects hydrodynamic forces and neutrophil adhesion rates in cone-plate viscometers.
Article in Biophysical journal, 2001. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed.
- The Impact of Mechanical Circulatory Support Devices on White Blood Cell Phenotype and Function.Cardiovascular engineering and technology · 2025Review
- A Review of Functional Analysis of Endothelial Cells in Flow Chambers.Journal of functional biomaterials · 2022Review
- A physical description of the adhesion and aggregation of platelets.Royal Society open science · 2017Article
- A Parallel-Plate Flow Chamber for Mechanical Characterization of Endothelial Cells Exposed to Laminar Shear Stress.Cellular and molecular bioengineering · 2016Article
- Role of fluid shear stress in regulating VWF structure, function and related blood disorders.Biorheology · 2015Review
- Analysis of a high-throughput cone-and-plate apparatus for the application of defined spatiotemporal flow to cultured cells.Biotechnology and bioengineering · 2013Article
- Application of Population Dynamics to Study Heterotypic Cell Aggregations in the Near-Wall Region of a Shear Flow.Cellular and molecular bioengineering · 2010Article
- Application of fluorescence spectroscopy to quantify shear-induced protein conformation change.Biophysical journal · 2009Article
- Shear stress induces internalization of E-cadherin and invasiveness in metastatic oesophageal cancer cells by a Src-dependent pathway.Cancer science · 2009Article
- Biological effects of dynamic shear stress in cardiovascular pathologies and devices.Expert review of medical devices · 2008Review
- Biomechanics of P-selectin PSGL-1 bonds: shear threshold and integrin-independent cell adhesion.Biophysical journal · 2006Article
- Hydrodynamic forces applied on intercellular bonds, soluble molecules, and cell-surface receptors.Biophysical journal · 2004Article
- Estimating the efficiency of cell capture and arrest in flow chambers: study of neutrophil binding via E-selectin and ICAM-1.Biophysical journal · 2002Article
- Platelet activation due to hemodynamic shear stresses: damage accumulation model and comparison to in vitro measurements.ASAIO journal (American Society for Artificial Internal Organs : 1992)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
We present a theoretical and experimental analysis of the effects of nonlinear flow in a cone-plate viscometer. The analysis predicts that flow in the viscometer is a function of two parameters, the Reynolds number and the cone angle. Nonlinear flow occurs at high shear rates and causes spatial variations in wall shear stress, collision frequency, interparticle forces and attachment times within the viscometer. We examined the effect of these features on cellular adhesion kinetics. Based on recent data (Taylor, A. D., S. Neelamegham, J. D. Hellums, et al. 1996. Biophys. J. 71:3488-3500), we modeled neutrophil homotypic aggregation as a process that is integrin-limited at low shear and selectin-limited at high shear. Our calculations suggest that selectin and integrin on-rates lie in the order of 10(-2)-10(-4)/s. They also indicate that secondary flow causes positional variations in adhesion efficiency in the viscometer, and that the overall efficiency is dependent not only on the shear rate, but also the sample volume and the cone angle. Experiments performed with isolated neutrophils confirmed these predictions. In these experiments, enhancing secondary flow by increasing the sample volume from 100 to 1000 microl at 1500/s for a 2 degrees cone caused up to an approximately 45% drop in adhesion efficiency. Our results suggest that secondary flow may significantly influence cellular aggregation, platelet activation, and endothelial cell mechanotransduction measurements made in the viscometer over the range of conditions applied in typical biological studies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.