Evidence map›Paper›PMID 11060065›Full record

ArticleJournal of clinical microbiology2000

Multicenter comparison of Roche COBAS AMPLICOR MONITOR version 1.5, Organon Teknika NucliSens QT with Extractor, and Bayer Quantiplex version 3.0 for quantification of human immunodeficiency virus type 1 RNA in plasma.

D G Murphy, L Côté, M Fauvel, P René, J Vincelette

Erratum issuedOpen access · bronzeAbstract readComparative StudyEvaluation StudyMulticenter Study
In one paragraph

Article in Journal of clinical microbiology, 2000. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 27 papers.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed
2.8field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed, 101 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Current practices in laboratory monitoring of HIV infection.The Indian journal of medical research · 2011
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Viral dynamics and in vivo fitness of HIV-1 in the presence and absence of enfuvirtide.Journal of acquired immune deficiency syndromes (1999) · 2008
    Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

  • Erratum issued
5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

D G MurphyLaboratoire de Santé Publique du Québec, Sainte-Anne-de-Bellevue, Montréal, Canada.
L Côté
M Fauvel
P René
J Vincelette
Centre hospitalier de l'Université Laval · CAHôpital Saint-Luc · CAUniversité de Montréal · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The performance and characteristics of Roche COBAS AMPLICOR HIV-1 MONITOR version 1.5 (CA MONITOR 1.5) UltraSensitive (usCA MONITOR 1. 5) and Standard (stCA MONITOR 1.5) procedures, Organon Teknika NucliSens HIV-1 RNA QT with Extractor (NucliSens), and Bayer Quantiplex HIV RNA version 3.0 (bDNA 3.0) were compared in a multicenter trial. Samples used in this study included 460 plasma specimens from human immunodeficiency virus (HIV) type 1 (HIV-1)-infected persons, 100 plasma specimens from HIV antibody (anti-HIV)-negative persons, and culture supernatants of HIV-1 subtype A to E isolates diluted in anti-HIV-negative plasma. Overall, bDNA 3.0 showed the least variation in RNA measures upon repeat testing. For the Roche assays, usCA MONITOR 1.5 displayed less variation in RNA measures than stCA MONITOR 1.5. NucliSens, at an input volume of 2 ml, showed the best sensitivity. Deming regression analysis indicated that the results of all three assays were significantly correlated (P < 0.0001). However, the mean difference in values between CA MONITOR 1.5 and bDNA 3.0 (0.274 log(10) RNA copies/ml; 95% confidence interval, 0.192 to 0.356) was significantly different from 0, indicating that CA MONITOR 1.5 values were regularly higher than bDNA 3.0 values. Upon testing of 100 anti-HIV-negative plasma specimens, usCA MONITOR 1.5 and NucliSens displayed 100% specificity, while bDNA 3.0 showed 98% specificity. NucliSens quantified 2 of 10 non-subtype B viral isolates at 1 log(10) lower than both CA MONITOR 1.5 and bDNA 3.0. For NucliSens, testing of specimens with greater than 1,000 RNA copies/ml at input volumes of 0.1, 0.2, and 2.0 ml did not affect the quality of results. Additional factors differing between assays included specimen throughput and volume requirements, limit of detection, ease of execution, instrument work space, and costs of disposal. These characteristics, along with assay performance, should be considered when one is selecting a viral load assay.

Indexed as

Branched DNA Signal Amplification AssayNucleic Acid Amplification TechniquesReverse Transcriptase Polymerase Chain ReactionCosts and Cost AnalysisDNA, ViralHIV-1HIV InfectionsHumansReagent Kits, DiagnosticReproducibility of ResultsRNA, ViralSensitivity and SpecificityViral LoadDNA, ViralReagent Kits, DiagnosticRNA, Viral

Identifiers

PMID11060065
PMCPMC87538
OpenAlexW2124622194

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.