Evidence map›Paper›PMID 10984458›Full record

ArticleGenome research2000

Rapid detection of deletion, insertion, and substitution mutations via heteroduplex analysis using capillary- and microchip-based electrophoresis.

H Tian, L C Brody, J P Landers

Open access · bronzeAbstract read
In one paragraph

Article in Genome research, 2000. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 99 citations in OpenAlex.

  1. Comprehensive study for BRCA1 and BRCA2 entire coding regions in breast cancer.Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2021
    Article
  2. Article
  3. Microfluidics and cancer: are we there yet?Biomedical microdevices · 2013
    Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Miniaturized detection technology in molecular diagnostics.Expert review of molecular diagnostics · 2005
    Review
  9. Rapid self-assembly of DNA on a microfluidic chip.Journal of nanobiotechnology · 2005
    Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

H TianDepartment of Chemistry, University of Pittsburgh, Pittsburgh, Pennsylvania 15260, USA.
L C Brody
J P Landers
National Institutes of Health · US

Funding

The role of the BRCA1 and BRCA2 gene in the pathogenesis of breast cancerZIAHG000120 · NHGRI · NATIONAL HUMAN GENOME RESEARCH INSTITUTE · PI BRODY, LAWRENCE C · 2009 to 2019
$980k
THE ROLE OF THE BRCA1 AND BRCA2 GENES IN THE PATHOGENESIS OF BREAST CANCERZ01HG000120 · NHGRI · NATIONAL HUMAN GENOME RESEARCH INSTITUTE · PI BRODY, LAWRENCE C · 1998 to 2008
$760k
6 · The paper itself

Abstract

In this report, we explore the potential of capillary and microchip electrophoresis for heteroduplex analysis- (HDA) based mutation detection. Fluorescent dye-labeled primers (6-FAM-tagged) were used to amplify the DNA fragments ranging from 130 to 400 bp. The effects of DNA fragment length, matrix additives, pH, and salt were evaluated for capillary electrophoresis- (CE) and/or microchip electrophoresis-based HDA, using six heterozygous mutations, 185delAG, E1250X (3867GT), R1443G (4446CG), 5382insC, 5677insA in BRCA1, and 6174delT in BRCA2. For this system, the effective fragment size for CE-based HDA was found in the range of 200-300 bp, however, the effective range was 150-260 bp for microchip-based HDA. Sensitivity studies show CE-based HDA could detect a mutated DNA present at only 1%-10% of the total DNA. Discrimination between wild-type and deletion or insertion mutations in BRCA1 and BRCA2 with CE-based HDA could be achieved in <8 min, while the substitution mutations required 14 min of analysis time. For each mutation region, 15 samples were run to confirm the accuracy and reproducibility of the method. Using the method described, two previously reported mutations, E1038G (3232AG, missense) and 4427 C/T (4427CT, polymorphism), were detected in the tested samples and confirmed by DNA sequencing. Translation of the CE-based methodology to the microchip format allowed the analysis time for each mutation to be decreased to 130 sec. Based on the results obtained with this model system, it is possible that CE-based HDA methodologies can be developed and used effectively in genetic testing. The fast separation time and automated operation afforded with CE instrumentation provide a powerful system for screening mutations that include small deletions, insertions, and point mutations. Translation to the microchip platform, especially to a multichannel microchip system, would allow for screening mutations with high throughput.

Indexed as

Biomarkers, TumorBRCA2 ProteinDNA PrimersElectrophoresis, CapillaryFemaleFluorescent DyesGenes, BRCA1Genetic MarkersHomozygoteHumansMutagenesis, InsertionalNeoplasm ProteinsNucleic Acid HeteroduplexesPoint MutationPolymerase Chain ReactionReproducibility of ResultsBiomarkers, TumorBRCA2 ProteinDNA PrimersFluorescent DyesGenetic MarkersNeoplasm ProteinsNucleic Acid HeteroduplexesTranscription Factors

Identifiers

PMID10984458
PMCPMC310899
OpenAlexW2159429023

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.