ArticleGenome research2000
Rapid detection of deletion, insertion, and substitution mutations via heteroduplex analysis using capillary- and microchip-based electrophoresis.
Article in Genome research, 2000. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 99 citations in OpenAlex.
- Comprehensive study for BRCA1 and BRCA2 entire coding regions in breast cancer.Clinical & translational oncology : official publication of the Federation of Spanish Oncology Societies and of the National Cancer Institute of Mexico · 2021Article
- A Low-Cost Palmtop High-Speed Capillary Electrophoresis Bioanalyzer with Laser Induced Fluorescence Detection.Scientific reports · 2018Article
- Microfluidics and cancer: are we there yet?Biomedical microdevices · 2013Review
- Sequence-based separation of single-stranded DNA using nucleotides in capillary electrophoresis: focus on phosphate.Electrophoresis · 2013Article
- Blinded study determination of high sensitivity and specificity microchip electrophoresis-SSCP/HA to detect mutations in the p53 gene.Electrophoresis · 2011Article
- Microfluidic platform for single nucleotide polymorphism genotyping of the thiopurine S-methyltransferase gene to evaluate risk for adverse drug events.The Journal of molecular diagnostics : JMD · 2007Article
- Clinical analysis by microchip capillary electrophoresis.Clinical chemistry · 2006Review
- Miniaturized detection technology in molecular diagnostics.Expert review of molecular diagnostics · 2005Review
- Rapid self-assembly of DNA on a microfluidic chip.Journal of nanobiotechnology · 2005Article
- Combined SSCP/duplex analysis by capillary electrophoresis for more efficient mutation detection.Nucleic acids research · 2001Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
In this report, we explore the potential of capillary and microchip electrophoresis for heteroduplex analysis- (HDA) based mutation detection. Fluorescent dye-labeled primers (6-FAM-tagged) were used to amplify the DNA fragments ranging from 130 to 400 bp. The effects of DNA fragment length, matrix additives, pH, and salt were evaluated for capillary electrophoresis- (CE) and/or microchip electrophoresis-based HDA, using six heterozygous mutations, 185delAG, E1250X (3867GT), R1443G (4446CG), 5382insC, 5677insA in BRCA1, and 6174delT in BRCA2. For this system, the effective fragment size for CE-based HDA was found in the range of 200-300 bp, however, the effective range was 150-260 bp for microchip-based HDA. Sensitivity studies show CE-based HDA could detect a mutated DNA present at only 1%-10% of the total DNA. Discrimination between wild-type and deletion or insertion mutations in BRCA1 and BRCA2 with CE-based HDA could be achieved in <8 min, while the substitution mutations required 14 min of analysis time. For each mutation region, 15 samples were run to confirm the accuracy and reproducibility of the method. Using the method described, two previously reported mutations, E1038G (3232AG, missense) and 4427 C/T (4427CT, polymorphism), were detected in the tested samples and confirmed by DNA sequencing. Translation of the CE-based methodology to the microchip format allowed the analysis time for each mutation to be decreased to 130 sec. Based on the results obtained with this model system, it is possible that CE-based HDA methodologies can be developed and used effectively in genetic testing. The fast separation time and automated operation afforded with CE instrumentation provide a powerful system for screening mutations that include small deletions, insertions, and point mutations. Translation to the microchip platform, especially to a multichannel microchip system, would allow for screening mutations with high throughput.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.