Evidence map›Paper›PMID 10810098›Full record

ArticleOccupational and environmental medicine2000

Heat exhaustion in a deep underground metalliferous mine.

A M Donoghue, M J Sinclair, G P Bates

Open access · bronzeAbstract read
In one paragraph

Article in Occupational and environmental medicine, 2000. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 36 papers.

0numbers the graph read from it
0cells of the map it votes in
36citing papers in PubMed
3.9field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

36 citing papers in PubMed, 169 citations in OpenAlex.

  1. Trial
  2. Review
  3. Article
  4. Climate Change Effects on the Predicted Heat Strain and Labour Capacity of Outdoor Workers in Australia.International journal of environmental research and public health · 2023
    Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Patterns of Heat Strain Among a Sample of US Underground Miners.Journal of occupational and environmental medicine · 2019
    Article
  14. Article
  15. Exertional heat illness: knowledge and behavior among construction workers.Environmental science and pollution research international · 2018
    Article
  16. Article
  17. Article
  18. Occupational heat stress in Australian workplaces.Temperature (Austin, Tex.) · 2016
    Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 1 country.

A M DonoghueMedical Centre, Mount Isa Mines, Queensland, Australia.
M J Sinclair
G P Bates
Curtin University · AUMount Medical Centre · AUUniversity of Queensland · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo examine the incidence, clinical state, personal risk factors, haematology, and biochemistry of heat exhaustion occurring at a deep underground metalliferous mine. To describe the underground thermal conditions associated with the occurrence of heat exhaustion.

methodsA 1 year prospective case series of acute heat exhaustion was undertaken. A history was obtained with a structured questionnaire. Pulse rate, blood pressure, tympanic temperature, and specific gravity of urine were measured before treatment. Venous blood was analysed for haematological and biochemical variables, during the acute presentation and after recovery. Body mass index (BMI) and maximum O2 consumption (VO2 max) were measured after recovery. Psychrometric wet bulb temperature, dry bulb temperature, and air velocity were measured at the underground sites where heat exhaustion had occurred. Air cooling power and psychrometric wet bulb globe temperature were derived from these data.

results106 Cases were studied. The incidence of heat exhaustion during the year was 43.0 cases/million man-hours. In February it was 147 cases/million man-hours. The incidence rate ratio for mines operating below 1200 m compared with those operating above 1200 m was 3.17. Mean estimated fluid intake was 0.64 l/h (SD 0.29, range 0.08-1.50). The following data were increased in acute presentation compared with recovery (p value, % of acute cases above the normal clinical range): neutrophils (p < 0.001, 36%), anion gap (p < 0.001, 63%), urea (p < 0.001, 21%), creatinine (p < 0.001, 30%), glucose (p < 0.001, 15%), serum osmolality (p = 0.030, 71%), creatine kinase (p = 0.002, 45%), aspartate transaminase (p < 0.001, 14%), lactate dehydrogenase (p < 0.001, 9.5%), and ferritin (p < 0.001, 26%). The following data were depressed in acute presentation compared with recovery (p value, % of acute cases below the normal clinical range): eosinophils (p = 0.003, 38%) and bicarbonate (p = 0.011, 32%). Urea and creatinine were significantly increased in miners with heat cramps compared with miners without this symptom (p < 0.001), but there was no significant difference in sodium concentration (p = 0.384). Mean psychrometric wet bulb temperature was 29.0 degrees C (SD 2.2, range 21.0-34.0). Mean dry bulb temperature was 37.4 degrees C (SD 2.4, range 31.0-43.0). Mean air velocity was 0.54 m/s (SD 0.57, range 0.00-4.00). Mean air cooling power was 148 W/m2 (SD 49, range 33-290) Mean psychrometric wet bulb globe temperature was 31.5 degrees C (SD 2.0, range 25.2-35.3). Few cases (< 5%) occurred at psychrometric wet bulb temperature < 25.0 degrees C, dry bulb temperature < 33.8 degrees C, air velocity > 1.56 m/s, air cooling power > 248 W/m2, or psychrometric wet bulb globe temperature < 28.5 degrees C.

conclusionHeat exhaustion in underground miners is associated with dehydration, neutrophil leukocytosis, eosinopenia, metabolic acidosis, increased glucose and ferritin, and a mild rise in creatine kinase, aspartate transaminase, and lactate dehydrogenase. Heat cramps are associated with dehydration but not hyponatraemia. The incidence of heat exhaustion increases during summer and at depth. An increased fluid intake is required. Heat exhaustion would be unlikely to occur if ventilation and refrigeration achieved air cooling power > 250 W/m2 at all underground work sites.

Indexed as

MetallurgyMiningAcute DiseaseAdultAir ConditioningAustraliaDehydrationFluid TherapyHeat ExhaustionHeat StrokeHot TemperatureHumansIncidenceMaleMiddle AgedOccupational Diseases

Identifiers

PMID10810098
PMCPMC1739920
OpenAlexW2167177857

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.