Evidence map›Paper›PMID 10796347›Full record

SynthesisThe Cochrane database of systematic reviews2000

Extramedullary fixation implants for extracapsular hip fractures.

M J Parker, H H Handoll, M A Chinoy

Abstract readSystematic Review
PubMed Publisher
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2000. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.

  1. Pooled it
  2. Extracts from "clinical evidence": hip fracture.BMJ (Clinical research ed.) · 2001
    Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

M J ParkerOrthopaedic Department, Peterborough District Hospital, Thorpe Road, Peterborough, Cambridgeshire, UK, PE3 6DA. mjparker@globalnet.co.uk
H H Handoll
M A Chinoy
Edinburgh Royal Infirmary · GBPeterborough City Hospital · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundExtramedullary fixation of hip fractures refers to the application of a plate and screws to the lateral side of the proximal femur.

objectivesTo compare different types of extramedullary fixation implants for the surgical treatment of extracapsular hip fracture in adults. SEARCH STRATEGY: We searched the Cochrane Musculoskeletal Injuries Group trials register and reference lists of relevant articles. Date of the most recent search: March 1998. SELECTION CRITERIA: All randomised or quasi-randomised trials comparing extramedullary implants used in the fixation of extracapsular hip fracture in adults. DATA COLLECTION AND ANALYSIS: All three reviewers independently assessed trial quality, using a ten item scale, and extracted data. Additional information was sought from all trialists. Wherever appropriate and possible, results of outcome measures were pooled by comparison. MAIN

resultsThe methodological quality of all six included trials was poor and in no trial was there clear concealment of allocation. Three trials involving 355 patients compared a fixed nail plate (Jewett or McLaughlin) with the sliding hip screw (SHS). The limited data presented indicated an increased risk of fixation failure outcomes for fixed nail plates. One trial involving 233 patients compared the RAB plate (a fixed angle blade plate with an oblique connecting strut) with the SHS. In this trial both implants had a high incidence of fixation failure. There was a tendency to a lower incidence of cut-out, re-operation, fixation failure, leg shortening, varus deformity and mortality for the RAB plate. None of the differences in these outcomes were statistically significant. One trial involving 100 patients compared the Pugh nail and the SHS. There was no significant difference between implants for the outcome measures reported. One trial involving 176 patients with 182 fractures, compared the Medoff plate with the SHS. A significantly higher mean operative blood loss and longer mean operative time were reported for the Medoff plate. There was however a tendency to a lower risk of fixation failure for unstable trochanteric fractures fixed with the Medoff plate. REVIEWER'S

conclusionsThe fixed nail plate was demonstrated to have to an increased risk of implant breakage and fixation failure in comparison to the SHS. Although the lack of evidence from randomised trials for other outcomes means that a firm conclusion of overall superiority of the SHS cannot be made, the increased fixation failure rate is a major consideration and indicates that the SHS is preferable. Insufficient information is available to draw firm conclusions of the clinical significance of differences between the SHS and either the RAB plate, the Pugh nail or the Medoff plate.