Evidence map›Paper›PMID 10777725›Full record

ArticleBiophysical journal2000

Cell property determination from the acoustic microscope generated voltage versus frequency curves.

T Kundu, J Bereiter-Hahn, I Karl

Open access · bronzeAbstract read
In one paragraph

Article in Biophysical journal, 2000. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
4.4field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 85 citations in OpenAlex.

  1. Article
  2. The Mechanics of Mitotic Cell Rounding.Frontiers in cell and developmental biology · 2020
    Review
  3. Article
  4. Article
  5. Article
  6. Localised micro-mechanical stiffening in the ageing aorta.Mechanisms of ageing and development · 2011
    Article
  7. Characterizing the elastic properties of tissues.Materials today (Kidlington, England) · 2011
    Article
  8. Quantifying Micro-mechanical Properties of Soft Biological Tissues with Scanning Acoustic Microscopy.Materials Research Society symposia proceedings. Materials Research Society · 2011
    Article
  9. Quantitative ultrasound backscatter for pulsed cavitational ultrasound therapy- histotripsy.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2009
    Article
  10. Mapping the Micromechanical Properties of Cryo-sectioned Aortic Tissue with Scanning Acoustic Microscopy.Materials Research Society symposia proceedings. Materials Research Society · 2009
    Article
  11. Article
  12. Article
  13. An acoustic microscopy technique reveals hidden morphological defenses in Daphnia.Proceedings of the National Academy of Sciences of the United States of America · 2004
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

T KunduDepartment of Civil Engineering, University of Arizona, Tucson, Arizona 85721 USA. tkundu@u.arizona.edu
J Bereiter-Hahn
I Karl
Goethe University Frankfurt · DEUniversity of Arizona · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Among the methods for the determination of mechanical properties of living cells acoustic microscopy provides some extraordinary advantages. It is relatively fast, of excellent spatial resolution and of minimal invasiveness. Sound velocity is a measure of the stiffness or Young's modulus of the cell. Attenuation of cytoplasm is a measure of supramolecular interactions. These parameters are of crucial interest for studies of cell motility, volume regulations and to establish the functional role of the various elements of the cytoskeleton. Using a phase and amplitude sensitive modulation of a scanning acoustic microscope (Hillman et al., 1994, J. Alloys Compounds. 211/212:625-627) longitudinal wave speed, attenuation and thickness profile of a biological cell are obtained from the voltage versus frequency or V(f) curves. A series of pictures, for instance in the frequency range 980-1100 MHz with an increment of 20 MHz, allows the experimental generation of V(f) curves for each pixel while keeping the lens-specimen distance unchanged. Both amplitude and phase values of the V(f) curves are used for obtaining the cell properties and the cell thickness profile. The theoretical analysis shows that the thin liquid layer, between the cell and the substrate, has a strong influence on the reflection coefficient and should not be ignored during the analysis. Cell properties, cell profile and the thickness of the thin liquid layer are obtained from the V(f) curves by the simplex inversion algorithm. The main advantages of this new method are that imaging can be done near the focal plane, therefore an optimal signal to noise ratio is achieved, no interference with Rayleigh waves occurs, and the method requires only an approximate estimate of the material properties of the solid substratum where the cells are growing on.

Indexed as

Cell Physiological PhenomenaAcousticsAnimalsBiomechanical PhenomenaBiophysical PhenomenaBiophysicsCell LineElasticityMicroscopyModels, BiologicalSurface PropertiesXenopus

Identifiers

PMID10777725
PMCPMC1300818
OpenAlexW2016591361

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked